Add host temperature telemetry and history
This commit is contained in:
@@ -354,6 +354,40 @@ journalctl -u electric-cherry-update.service -n 100
|
||||
|
||||
## Placement and resource capacity
|
||||
|
||||
### Host temperature
|
||||
|
||||
Agent **1.10.0** reports temperature sensors exposed by supported Linux hwmon
|
||||
drivers without installing additional packages. **Hosts** shows CPU temperature
|
||||
beneath CPU usage. A host's **Overview → Inventory** shows the selected reading
|
||||
and expandable **Temperature sensors**, including per-core and storage details.
|
||||
Stale readings are marked as last reported; absent or failed readings are
|
||||
**Unavailable**, never zero or a readiness failure.
|
||||
|
||||
**Fleet → Capacity → Temperature history** uses the existing host selector and
|
||||
Last hour / 24 hours / 7 days controls. **All hosts** displays a separate CPU line
|
||||
for each host. Select one host to add its NVMe composite and chipset lines using
|
||||
the legend. Hover, tap, or use the arrow keys on the chart to inspect a period.
|
||||
Each host page's **Capacity** button opens the view filtered to that host.
|
||||
The game filter affects launch estimates, not temperatures.
|
||||
|
||||
The CPU reading is the hottest reported package, falling back to a physical
|
||||
AMD die/CCD and then a core reading. AMD Tctl cooling-control values are excluded
|
||||
because they may include an offset. Supported device drivers are `coretemp`,
|
||||
`k10temp`, `nvme` and `pch_*`; sensor availability depends on hardware and drivers.
|
||||
Virtual machines and older agents may have no supported readings. Missing,
|
||||
faulty and disabled sensors are skipped individually.
|
||||
|
||||
Temperature history starts after the agent upgrade. The controller stores one
|
||||
peak per sensor per minute, limited to the CPU summary and up to sixteen NVMe
|
||||
composite/chipset inputs per host. Longer chart periods show the maximum of
|
||||
those peaks; a period without readings remains a gap. Brief gaps within an
|
||||
aggregated period may still leave a peak for that period. **Host resource history
|
||||
retention** applies to CPU, memory and temperature samples (seven days by default;
|
||||
zero keeps them indefinitely). Series colors identify hosts/sensors and do not
|
||||
indicate thermal safety. Temperature does not change placement or trigger alerts.
|
||||
|
||||
### CPU and memory capacity
|
||||
|
||||
### Host inventory and eligibility
|
||||
|
||||
The Inventory panel shows CPU usage with agent 1.4.2 and later. It measures
|
||||
|
||||